Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (2024)

by Tim David

FacebookXReddit

If you are dealing with a Sw Open message on your Raypak heater, I have a solution for you! Over my years of fixing Raypak heaters, the Sw is one of the more common issues I get calls on. A Raypak heater is typically equipped with a pressure switch that only allows the heater to fire up when there is sufficient water flow.

Q: I am trying to turn on my Raypak pool heater for the season and getting a RollOut Sw Open error on the monitor. How can I fix this? – Ron Wells

Problem: Your pool heater might show an error indicating a problem with the rollout switch. This switch is a critical safety feature designed to prevent the heater from overheating or catching fire. It’s a common issue that can cause your pool heater to malfunction.

Solution: (From Tim at Airlucent) The issue was successfully fixed by identifying and replacing a faulty rollout switch in the Raypak natural gas pool heater. I first confirmed the error message on the heater’s display, which indicated a problem with the rollout switch. This switch is a crucial safety component that prevents overheating and potential fire hazards. I tested the switch for continuity using a voltmeter and found it was burnt out, necessitating a replacement. Before installing the new switch, I inspected the exhaust and combustion chamber for any blockages or debris, as these could cause similar issues. After replacing the switch and ensuring there were no other signs of damage or malfunction, the heater resumed normal operation. It’s important to note that while replacing the rollout switch is a straightforward task, it’s essential to prioritize safety and seek professional assistance if unsure about any steps in the process.

Sale

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (1)

Raypak 005899F Thermal Cut-Off Fuse 106/156-Kit

  • Raypak Inc. Part Number: 005899F
  • Catalog Part Number: 6234-36

It must be noted, however, that the pressure switch is only suitable for determining water pressure in a heater installation where the inlet/outlet water piping is 150 mm below or above the pool level. Otherwise, it doesn’t work and could be the reason for the SW open error.

Or if you need a new Raypak heater, check these new models:

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (3)

Raypak 266,000 BTU Digital Electronic Ignition Natural Gas Pool Heater

  • Built to withstand various weather conditions, perfect solution for environments requiring efficiency, convenience and versatility.
  • Intermittent spark ignition pilot safety controls. Pilot only comes on when there is a call for heat.

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (4)

Raypak 105,000 BTU Swimming Pool and Spa Heater – Natural Gas

  • Designed for easy installation on above ground pools, smaller in-ground pools, and spas
  • Standard 120v 3-prong power cord or can be easily converted to 220v

Step-By-Step Instructions for Fixing the Sw Error Code

If you’re encountering only a Sw Open error with your pool heater, it’s likely due to a restriction in water flow. Here’s a detailed guide to help you troubleshoot and fix this issue:

  1. Inspect Shut-off Valves: Begin by checking the plumbing around your pool heater. Look for any shut-off valves that might be closed. Ensure all water valves are open and positioned correctly to allow normal water flow to the pool.
  2. Check Inlet/Outlet Bypass Valves: Verify if any bypass valves are open. If you find them open, close them. Open bypass valves can restrict water flow to the heater, leading to the SW open Code.
  3. Clear Obstructions in Intake: Investigate the heater’s intake for any obstructions. Removing these blockages should get your heater working again.
  4. Clean Water Filters: Ensure that both the pump basket and the skimmer basket are clean and free from debris, like leaves. Clogged filters are a common cause of restricted water flow. After cleaning, check if the heater functions properly. If it does, regular filter maintenance might be needed. Depending on your model, clean the cartridges or backwash the filter.
  5. Test Pressure Switch: Use a multimeter to test the ends of the pressure switch for continuity. Also, check for any loose wires. If there’s no voltage, the pressure switch might be defective and may need replacement.
  6. Adjust the Pressure Switch: Incorrectly set pressure switches can trigger the SW error. Refer to your heater’s manual for guidance on adjusting the pressure switch.
  7. Secure Loose Wires on Pressure Switch: Check for any loose wires on the pressure switch and securely reattach them.
  8. Check Recirculation Pump: Ensure that the recirculation pump is operational and not set too low. A malfunctioning pump can lead to insufficient water flow.

Note: Even if water intake appears normal in the pool, there could still be a flow restriction significant enough to trigger the SW error. Regular maintenance and checks are key to preventing such issues.

Final Thought

We have seen that the SW open message on your Raypak heater is commonly triggered by issues relating to the pressure switch. That is a problematic pressure switch or an insufficient flow of water into the heater.

That said, there are a few things you can do to keep your pool heater running in great condition. These include:

1. Monitoring chlorine and PH levels of your pool water regularly (depending on what is recommended in the user manual.)

2. Do not run your heater if the water balance is out of the parameters specified by your manufacturer.

Have a question about pool heaters? Airlucent owner Tim David would like to answer your question in an upcoming article, call (256) 399-9708 or contact David via the contact page.

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (5)

Tim David

HVAC tech with over 30 years of experience. Retired and doing repair work on the side around Madison County, AL.

FacebookXReddit

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (2024)

FAQs

What does water sw open mean on RayPak pool heater? ›

The sw water error is telling you the flow of water through the heater is not sufficient to start the heater. This is typically due to a dirty filter. If a sand filter backwash. If a cartridge or de filter remove and clean.

What does rollout SW open mean on my Rheem pool heater? ›

Hello,My name is Billy. This is generally a heat activated switch down by the burners. If the vent gets plugged, the heat exchanger...even high winds...can force the flame/heat backwards and trip this switch. Some are able to be reset others need to be replaced.

What causes a rollout switch to open? ›

The flame rollout sensor will only trip if the furnace has an underlying problem, such as blocked vents, overheating, or gas pressure issues. Ensure that you don't opt to keep resetting the switch and keeping the furnace running.

How do you troubleshoot a Raypak pool heater? ›

Go make sure there aren't any tripped circuit breakers in the fuse box, then check that the unit's time clock is set to the “On” position. Check Filters & Strainers: Problems with slow or inefficient heating, as well as overly noisy operation, can sometimes be traced back to dirty filters and strainers.

What does open water sensor mean on pool heater? ›

(open water temp sensor) That means the control board can no longer read the temperature of the incoming water. It is a common issue. Solution is first check wiring connection of sensor at the control board, but most likely sensor is defective and needs to be replaced.

What causes flame rollout on a water heater? ›

Causes of Water Heater Flame Roll-Out

A clogged or damaged burner. A lack of combustion air. Incorrect vent pipe sizing, routing or termination. A blockage in the vent pipe.

Why does my Raypak pool heater keep shutting off? ›

If one day you wake up and your pool heat pump stops running, the first thing to check is your water flow. Without an adequate source of water, a pool heat pump automatically shuts down to prevent overheating. This is sometimes the cause of what many describe as a pool heat pump turning off and on.

What does roll out switch mean? ›

Your furnace has a safety device that is designed to detect flame. rollouts. It's called a flame rollout switch, and it cuts off the. gas supply to your furnace when it detects higher temperatures than normal. immediately outside the combustion chamber.

Is the flame rollout switch normally open or closed? ›

The flame rollout switch is normally closed and opens on high temperature from the flame. The switch is meant to open if the flame is pushed backward away from the heat exchanger area where the flame should be traveling toward.

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Greg Kuvalis

Last Updated:

Views: 6295

Rating: 4.4 / 5 (75 voted)

Reviews: 82% of readers found this page helpful

Author information

Name: Greg Kuvalis

Birthday: 1996-12-20

Address: 53157 Trantow Inlet, Townemouth, FL 92564-0267

Phone: +68218650356656

Job: IT Representative

Hobby: Knitting, Amateur radio, Skiing, Running, Mountain biking, Slacklining, Electronics

Introduction: My name is Greg Kuvalis, I am a witty, spotless, beautiful, charming, delightful, thankful, beautiful person who loves writing and wants to share my knowledge and understanding with you.